Bridge #24
Built 1910 (116 yrs ago)
Closed to traffic
Pony Truss
Bridge #24
Pony Truss
Built 1910
76.00 ft
Built
1910
Type
Pony Truss
Style
Pratt
Length
76.00 ft
Main span
60.00 ft
Spans
1
About
4 panel pin connected pratt pony truss
Identity & location
- NBI Number
- 002050000000000
- Structure Number
- 24N2960E0560002
- Carries
- N2960
- Crosses
- Wolf Creek
- Year Built
- 1910
Structure
1 × 60.00ft Pratt Pony Truss span (4 panels)
- Bridge Type
- Pony Truss
- Main Span Style
- Pratt
- Overall Length
- 76.00 ft
- Main Span Length
- 60.00 ft
- Deck Width
- 16.00 ft
- Main Spans
- 1
- Main Span Panels
- 4
Appears in datasets
ODOT Off System Bridges NBI
Survey data vs. current bridge record
| Field | Survey | Bridge | |
|---|---|---|---|
| NBI No | 00205 | 00205 | ✓ |
| Structure No | 24N2960E0560002 | 24N2960E0560002 | ✓ |
| ODOT BRKEY | 205 | — | ⚠ |
| County | Garfield | Garfield | ✓ |
| Facility Carried | N2960 | N2960 | ✓ |
| Feature | WOLF CREEK | Wolf Creek | ✓ |
| Alt Name | 24N2960E0560002 | — | ⚠ |
| Description | 60ft. PONY TRUSS SPAN | 4 panel pin connected pratt pony truss | ✗ |
| Year Built | 1910 | 1910 | ✓ |
| Latitude | 36.19985278 | 36.1998333 | ✗ |
| Longitude | -97.72988056 | -97.7297500 | ✗ |
| Overall Length | 76.001 | 76.00 | ✗ |
| Deck Width | 16.001 | 16.00 | ✗ |
| Main Spans | 1 | 1 | ✓ |
| Skew | 0 | — | ⚠ |
| Lanes | 1 | — | ⚠ |
| Road Width | 15.499 | — | ⚠ |
| Material | 3 - Steel | — | ⚠ |
| Design | Truss — Thru (10) | — | ⚠ |
| Span Type Main | Main span (M) | — | ⚠ |
| Deck Structure | Wood or Timber (8) | — | ⚠ |
| Open / Closed | Closed (K) | — | ⚠ |
| Sufficiency | 16.8 | — | ⚠ |
| Structure Rating | Failed (0) | — | ⚠ |
| Deck Rating | Failed (0) | — | ⚠ |
| Super Rating | Failed (0) | — | ⚠ |
| Sub Rating | Failed (0) | — | ⚠ |
| Culvert Rating | Not applicable (N) | — | ⚠ |
| Owner | 02 - County Highway Agency | — | ⚠ |
| Custodian | 02 - County Highway Agency | — | ⚠ |
| Hwy System | 0 - Off Highway | — | ⚠ |
| Functional Class | 09 - Local (Rural) | — | ⚠ |
| Bridge System | D | — | ⚠ |
| ADT | 25 | — | ⚠ |
| ADT Year | 2022 | — | ⚠ |
| Historical | 5 | — | ⚠ |
Source: Oklahoma Department of Transportation (ArcGIS / NBI) · Imported May 6, 2026
Oklahoma Spans of Time 2021
Survey data vs. current bridge record
| Field | Survey | Bridge | |
|---|---|---|---|
| County | Garfield | Garfield | ✓ |
| NBI No | 00205 | 00205 | ✓ |
| Structure No | 24N2960E0560002 | 24N2960E0560002 | ✓ |
| Facility Carried | N2960 | N2960 | ✓ |
| Feature | Bitter Creek | — | ⚠ |
| Truss Type | Pratt Pony Truss | Pony Truss | ✗ |
| Year Built | 1910 | 1910 | ✓ |
| NRHP Listed | No | ✓ | |
| NRHP Eligible | Yes | — | ⚠ |
| NRHP Criteria | Eligible (C) | — | ⚠ |
Source: Oklahoma Department of Transportation · Imported May 7, 2026
Oklahoma Spans of Time 2007
Survey data vs. current bridge record
| Field | Survey | Bridge | |
|---|---|---|---|
| County | Garfield | Garfield | ✓ |
| Structure No | 24N2960E0560002 | 24N2960E0560002 | ✓ |
| Build Date | 1910 | 1910 | ✓ |
| Bridge Type | Pony Truss | Pony Truss | ✓ |
| Num Spans | 2 | 1 | ✗ |
| Total Length | 76 | 76.00 | ✗ |
| Longest Span | 60 | 60.00 | ✗ |
| Builder Plate | No | — | ⚠ |
| Connections | pinned | — | ⚠ |
| Builder | — | ⚠ | |
| Curb Width | 16 | — | ⚠ |
| NR Eligible | No | — | ⚠ |
Source: Oklahoma Department of Transportation · Imported May 4, 2026
Oklahoma Spans of Time 1993
Survey data vs. current bridge record
| Field | Survey | Bridge | |
|---|---|---|---|
| County | Garfield | Garfield | ✓ |
| Structure Number | 24N2960E0560002 | 24N2960E0560002 | ✓ |
| Built Year | 1910 | 1910 | ✓ |
| Bridge Type | Pony Truss | Pony Truss | ✓ |
| Bridge Design | Pratt | — | ⚠ |
| Num Spans | 2 | 1 | ✗ |
| Total Length | 76 | 76.00 | ✗ |
| Main Span Length | 60 | 60.00 | ✗ |
| Builder Plate | No | — | ⚠ |
| Connections | pinned | — | ⚠ |
| Curb Width | 16 | — | ⚠ |
| NRHP Listed | No | ✓ |
Source: Oklahoma Department of Transportation / Spans of Time (1993) · Imported May 6, 2026
All surveys vs. bridge record
4 surveys · 46 fields
| Field | Bridge | 2026 | 2021 | 2007 | 1993 |
|---|---|---|---|---|---|
| NBI No | 00205 | 00205 ✓ | 00205 ✓ | — | — |
| Structure No | 24N2960E0560002 | 24N2960E0560002 ✓ | 24N2960E0560002 ✓ | 24N2960E0560002 ✓ | 24N2960E0560002 ✓ |
| ODOT BRKEY | — | 205 | — | — | — |
| County | Garfield | Garfield ✓ | Garfield ✓ | Garfield ✓ | Garfield ✓ |
| Facility Carried | N2960 | N2960 ✓ | N2960 ✓ | — | — |
| Feature | Wolf Creek | WOLF CREEK ✓ | Bitter Creek ✗ | — | — |
| Alt Name | — | 24N2960E0560002 | — | — | — |
| Description | 4 panel pin connected pratt pony truss | 60ft. PONY TRUSS SPAN ✗ | — | — | — |
| Year Built | 1910 | 1910 ✓ | 1910 ✓ | 1910 ✓ | 1910 ✓ |
| Latitude | 36.1998333 | 36.19985278 ✗ | — | — | — |
| Longitude | -97.7297500 | -97.72988056 ✗ | — | — | — |
| Overall Length | 76.00 | 76.001 ✗ | — | — | — |
| Deck Width | 16.00 | 16.001 ✗ | — | — | — |
| Main Spans | 1 | 1 ✓ | — | — | — |
| Skew | — | 0 | — | — | — |
| Lanes | — | 1 | — | — | — |
| Roadway / Curb Width | — | 15.499 | — | 16 | 16 |
| Material | — | 3 - Steel | — | — | — |
| Design | — | Truss — Thru (10) | — | — | — |
| Span Type Main | — | Main span (M) | — | — | — |
| Deck Structure | — | Wood or Timber (8) | — | — | — |
| Open / Closed | — | Closed (K) | — | — | — |
| Sufficiency | — | 16.8 | — | — | — |
| Structure Rating | — | Failed (0) | — | — | — |
| Deck Rating | — | Failed (0) | — | — | — |
| Super Rating | — | Failed (0) | — | — | — |
| Sub Rating | — | Failed (0) | — | — | — |
| Culvert Rating | — | Not applicable (N) | — | — | — |
| Owner | — | 02 - County Highway Agency | — | — | — |
| Custodian | — | 02 - County Highway Agency | — | — | — |
| Hwy System | — | 0 - Off Highway | — | — | — |
| Functional Class | — | 09 - Local (Rural) | — | — | — |
| Bridge System | — | D | — | — | — |
| ADT | — | 25 | — | — | — |
| ADT Year | — | 2022 | — | — | — |
| Historical | — | 5 | — | — | — |
| Truss Type | Pony Truss | — | Pratt Pony Truss ✗ | Pony Truss ✓ | Pony Truss ✓ |
| NRHP Listed | — | No ✓ | — | No ✓ | |
| NRHP Eligible | — | — | Yes | No | — |
| NRHP Criteria | — | — | Eligible (C) | — | — |
| Num Spans | 1 | — | — | 2 ✗ | 2 ✗ |
| Total Length | 76.00 | — | — | 76 ✗ | 76 ✗ |
| Main / Longest Span | 60.00 | — | — | 60 ✗ | 60 ✗ |
| Builder Plate | — | — | — | No | No |
| Connections | — | — | — | pinned | pinned |
| Bridge Design | — | — | — | — | Pratt |
✓ matches the bridge record · ✗ differs · blank in the Bridge column means the bridge record has no value for that field.